Modelling Options: Stiffness: Tendon Elements
One longitudinal action. The member has no stiffness but applies forces to
nodes K and L and hence forces and moments
to nodes I and J.
- Constant forces depending on magnitude and sign of the member displacement.
- Force proportional to nodal displacements, velocities or accelerations (with
up to 10 contributions from different nodes and actions).
- Re-settable Actuator (semi-active damper) model.